Marioff home page HI-FOG home page

English Suomeksi På svenska Français По-русски

Feedback

Legal Notice

Site map

Club Marioff

ABOUT MARIOFF

PRODUCTS

CONTACTS

NEWS & INFORMATION

CAREERS

 
Metro escalators in Madrid

> 

Fire protection solutions

 

> 

Technology

> 

Benefits & Features

> 

Marine & offshore applications

> 

Land-based applications

 

> 

Computer & Telecom

> 

Transportation infrastructure

 

> 

Road & Rail tunnels

> 

Underground railway stations

> 

Trains

> 

Industrial applications

> 

Aircraft hangars

> 

Museums & heritage buildings

> 

Commercial & public buildings

> 

Food industry

> 

References


> 

Projects & service


Read more
Printable version

Printable version


Printable version

Download brochure "Fire protection of metros"
in English
in German

Read more
Examples of transportation infrastructure protected by
HI-FOG

 

Products > Fire protection solutions > Land-based applications >
Transportation infrastructure
> Metro systems

Fire protection of underground raliway systems

The fire risks in urban underground transport systems or metros are amplified by the problems associated with mass evacuation of people in case of emergency. The primary danger is that posed by smoke, as this is difficult to vent in a controlled way from an underground space.

Although most underground rail systems now operate no-smoking policies, a small minority of people disregard the rules and a casually dropped cigarette butt is the biggest fire danger. There is a particular danger if this occurs on an escalator where there is also a risk of fire from major mechanical failure. Fires can also occur due to overheating of electric cables or equipment in transformer & switchgear rooms, control rooms, garbage rooms, store rooms and retail shops. Fires can also result from accidents during refurbishment work. They may also be deliberately started by an arsonist.

Because of the dangers of smoke underground, the primary objective of fixed fire protection systems must be to rapidly extinguish or suppress a fire so that smoke is minimised and surrounding areas are cooled so that re-ignition cannot occur. Systems must be extremely reliable and ideally capable of being frequently tested to ensure operational readiness. They should also not be harmful to people or a danger to equipment or the environment, whether set off in case of fire or accidentally discharged.

» More information More information

State of the art

Many urban underground transport systems have limited fixed fire protection systems, relying on smoke detection and manual intervention of security staff with back-up from fire services. Escalators however have normally been protected by Halon or water spray systems. Storage and retail areas may be protected by sprinkler or water spray systems. Gaseous extinguishing systems have also been used to protect store rooms, control rooms, transformer and switchgear rooms.

There are specific disadvantages to the use of conventional water-based systems in underground applications. Installation of large bore piping and equipment may be virtually impossible, particularly in areas some distance underground. Systems are inefficient so large volumes of smoke may be produced before the fire is extinguished. Also, removing large volumes of discharged water can present a real difficulty. For environmental reasons most Halon systems have now been replaced, but gaseous systems are generally unsuitable for most underground railway risks because of the difficulty of guaranteeing enclosure integrity.

Water mist is therefore increasingly recognised as the most suitable fixed fire protection technology for protecting underground rail systems. Water mist is safe for people and the environment. High radiant heat blocking means that equipment near the fire is not damaged. Because of small piping sizes, water mist systems can be easily installed in existing stations and equipment such as escalators. Systems use water efficiently so smoke output is minimised, and discharge rates are low so water removal is not an issue. Total flooding water mist systems are ideal for smaller spaces because a gas-tight enclosure is not necessary.

HI-FOG solution - features and benefits

Marioff has developed a range of HI-FOG water mist fire protection solutions for a wide variety of applications. For underground rail complexes systems have been designed for the specific risks and operating conditions. Escalators and other risk spaces in a single station are normally connected to a single central pump and water storage unit that can operate for a short time in an emergency without electric power. Small individual rooms can be economically protected by pre-engineered 'total flooding' HI-FOG sprinkler systems requiring no external detection, water or electric supply.

Fast suppression or extinguishing is achieved with a water discharge rate 70-90% less than conventional water-based systems. Small bore 16 and 30 mm pipes are prepared on site so no pre-planning is required. Piping can be clamped directly to walls, so retrofitting existing stations is easy and design and civil engineering costs are minimised. A complete HI-FOG system can be installed on an escalator in just one day. All HI-FOG metro systems are designed to be frequently tested to ensure operational readiness.

HI-FOG details

A HI-FOG system for protecting underground rail complexes will consist of the escalator sub-systems and other designated risk spaces connected by small bore stainless steel piping via selector valves to the centralised pump and water storage unit. The escalator sub-systems utilise a fast-acting detection system to activate a number of open spray heads simultaneously. Local manual over-ride activation is also provided in case of failure of the detection system. Other risk spaces such as transformer rooms and retail shops are normally protected by HI-FOG automatic sprinklers, again connected via selector valves to the centralised unit.

The centralised HI-FOG (SPU) pump and water storage unit is electrically-driven and dimensioned for simultaneous operation at two escalators. It incorporates a water supply tank and an emergency nitrogen powered GPU (Gas-driven Pump Unit) in case of complete electric power failure.

Remote spaces can be protected by Marioff's SCAU (Self Contained Accumulator Unit). The Unit uses stored nitrogen cylinders and non-pressurised water cylinders. A signal from the detection system opens a valve to release the nitrogen, which drives the water from the water cylinders in a controlled sequence to the HI-FOG nozzles or sprinklers.